Event Reporting: Templates and Codes
D–19
020D2401
The wrong write cache module is configured. The serial numbers do not
match. Either the existing or the expected cache contains dirty write-
back cached data. Note that in this instance the Memory Address, Byte
Count, FX Chip Register, Memory Controller register, and Diagnostic
register fields are undefined.
14
020E2401
The write cache module is missing. A cache is expected to be configured
and contains dirty write-back cached data. Note that in this instance the
Memory Address, Byte Count, FX Chip Register, Memory Controller
register, and Diagnostic register fields are undefined.
14
02102401
The write cache modules are not configured properly for a dual-
redundant configuration. One of the cache modules is not the same size
to perform cache failover of dirty write-back cached data. Note that in
this instance the Memory Address, Byte Count, FX Chip Register,
Memory Controller register, and Diagnostic register fields are undefined.
14
02110064
Disk Bad Block Replacement attempt completed for a read within the
user data area of the disk. Note that due to the way Bad Block
Replacement is performed on SCSI disk drives, information on the
actual replacement blocks is not available to the controller and is
therefore not included in the event report.
51
021A0064
Disk Bad Block Replacement attempt completed for a write of controller
metadata to a location outside the user data area of the disk. Note that
due to the way Bad Block Replacement is performed on SCSI disk
drives, information on the actual replacement blocks is not available to
the controller and is therefore not included in the event report.
41
021B0064
Disk Bad Block Replacement attempt completed for a read of controller
metadata from a location outside the user data area of the disk. Note that
due to the way Bad Block Replacement is performed on SCSI disk
drives, information on the actual replacement blocks is not available to
the controller and is therefore not included in the event report.
41
021D0064
Unable to lock the other controller’s cache in a write-cache failover
attempt. Either a latent error could not be cleared on the cache or the
other controller did not release its cache. Note that in this instance the
Memory Address, Byte Count, FX Chip register, Memory Controller
register, and Diagnostic register fields are undefined.
14
021E0064
The device specified in the Device Locator field has been added to the
RAIDset associated with the logical unit.The RAIDset is now in
Reconstructing state.
51
02280064
The device specified in the Device Locator field has been added to the
Mirrorset associated with the logical unit. The new Mirrorset member is
now in Copying state.
51
Table D–1
Instance Codes (Continued)
Instance
Code
Description
Template