HSG80 User’s Guide

9. Insert the new cache module into its slot and engage its retaining levers.

Note In mirrored mode, FRUTIL will initialize the mirrored portion of
the new cache module, check for old data on the cache module, and
then restart all device ports. After the device ports have been restarted,
FRUTIL will test the cache module and the ECB. After the test
completes, the device ports will quiesce and a mirror copy of the cache
module data will be created on the newly installed cache module.

FRUTIL displays the following:

The configuration has two controllers.

To restart the other controller:

1. Type ’restart other_controller’.

2. Press and hold the reset button while inserting the

program card on the slot A [or B] controller, then

release the reset button.

The controller will restart.

Field Replacement Utility terminated.

10. To allow the “other controller” to restart, type the following command:

RESTART OTHER _CONTROLLER

11. Hold the reset button while inserting the program card into the

controller. Release the reset button and replace the ESD cover. The
controller will restart.

12. Enable failover, and re-establish the dual-redundant configuration with

the following command:

SET FAILOVER COPY=THIS_CONTROLLER

This command copies the subsystem’s configuration from “this
controller” to the “other controller.”

13. Disconnect the PC or terminal from the controller’s maintenance port.