Replacing an I/O Module

Figure 5–6 shows a rear view of the BA370 enclosure and the location
of the six I/O modules (also referred to as ports). Use the following
steps to replace an I/O module:

Note This procedure is not applicable for the M1 shelf.

An I/O module can be replaced in either a single-controller or a dual-
redundant controller configuration using this procedure.

Figure 5–6 I/O Module Locations in a BA370 Enclosure

Note The controller can function with one failed I/O module.

1. Connect a PC or terminal to the controller’s maintenance port.

2. In a dual-redundant controller configuration, disable failover with the

following command:

SET NOFAILOVER

3. In a dual-redundant controller configuration, remove the program card’s

ESD cover and program card from the other controller. Save them for
reinstallation.

4. Start FRUTIL with the following command:

RUN FRUTIL

FRUTIL displays the following:

Do you intend to replace this controller’s cache battery? Y/N

Rear view

Fan

Fan

Port 6

Port 2

Port 4

Port 5

Port 1

Port 3

CXO6289A