HP Array Controller HSG V8.7 Software User Manual
Page 488
D–54
HSG80 User’s Guide
030B0188
A dip error was detected when pcb_busy was set.
n
Last Failure Parameter [0] contains the PCB port_ptr value.
n
Last Failure Parameter [1] contains the new info NULL-SSTAT0-DSTAT-ISTAT.
n
Last Failure Parameter [2] contains the PCB copy of the device port DBC register.
n
Last Failure Parameter [3] contains the PCB copy of the device port DNAD
register.
n
Last Failure Parameter [4] contains the PCB copy of the device port DSP register.
n
Last Failure Parameter [5] contains the PCB copy of the device port DSPS
register.
n
Last Failure Parameter [6] contains the PCB copies of the device port SSTAT2/
SSTAT1/SSTAT0/DSTAT registers.
n
Last Failure Parameter [7] contains the PCB copies of the device port LCRC/
RESERVED/ISTAT/DFIFO registers.
031E0100
Can’t find in_error dwd on in-process queue.
031F0100
Either DWD_ptr is null or bad value in dsps.
03280100
SCSI CDB contains an invalid group code for a transfer command.
03290100
The required Event Information Packet (EIP) or Device Work Descriptor (DWD) were
not supplied to the Device Services error logging code.
032B0100
A Device Work Descriptor (DWD) was supplied with a NULL Physical Unit Block
(PUB) pointer.
03320101
An invalid code was passed to the error recovery thread in the error_stat field of the
PCB.
n
Last Failure Parameter[0] contains the PCB error_stat code.
Table D–3
Last Failure Codes (Continued)
Code
Description