HSG80 User’s Guide

0256000A

The write operation failed because the unit is Data Safety Write
Protected. The Information field of the Device Sense Data contains the
block number of the first block in error.

51

0257000A

An attempt to reassign a bad disk block failed. The contents of the disk
block is lost. The Information field of the Device Sense Data contains
the block number of the first block in error.

51

0258000A

This command was aborted prior to completion. The Information field
of the Device Sense Data contains the block number of the first block in
error.

51

0259000A

The write operation failed because the unit is hardware write protected.
The Information field of the Device Sense Data contains the block
number of the first block in error.

51

025A000A

The command failed because the unit became inoperative prior to
command completion. The Information field of the Device Sense Data
contains the block number of the first block in error.

51

025B000A

The command failed because the unit became unknown to the controller
prior to command completion. The Information field of the Device
Sense Data contains the block number of the first block in error.

51

025C000A

The command failed because of a unit media format error. The
Information field of the Device Sense Data contains the block number of
the first block in error.

51

025D000A

The command failed for an unknown reason. The Information field of
the Device Sense Data contains the block number of the first block in
error

51

025F2201

Memory diagnostics performed during controller initialization detected
an excessive number (512 pages or more) of memory errors detected on
the primary cache memory. Diagnostics have not declared the cache
failed, due to the isolated bad memory regions, but this is a warning to
replace the cache as soon as possible in case of further degradation. The
software performed the necessary error recovery as appropriate. Note
that in this instance the Memory Address and Byte Count fields are
undefined.

14

02603A01

Memory diagnostics performed during controller initialization detected
an excessive number (512 pages or more) of memory errors detected on
mirrored cache memory. Diagnostics has not declared the cache failed,
due to the isolated bad memory regions, but this is a warning to replace
the cache as soon as possible in case of further degradation. The
software performed the necessary error recovery as appropriate. Note
that in this instance the Memory Address, Byte Count fields are
undefined.