HP Array Controller HSG V8.7 Software User Manual
Page 461

Event Reporting: Templates and Codes
D–27
0311430A
Nonvolatile memory and drive metadata indicate conflicting drive
configurations.
51
0312430A
The Synchronous Transfer Value differs between drives in the same
storageset.
51
03134002
Maximum number of errors for this data transfer operation exceeded.
51
03144002
Drive reported recovered error without transferring all data.
51
03154002
Data returned from drive is invalid.
51
03164002
Request Sense command to drive failed.
51
03170064
Illegal command for pass through mode.
51
03180064
Data transfer request error.
51
03194002
Premature completion of a drive command.
51
031A4002
Command timeout.
51
031B0101
Watchdog timer timeout.
51
031C4002
Disconnect timeout.
51
031D4002
Unexpected bus phase.
51
031E4002
Disconnect expected.
51
031F4002
ID Message not sent by drive.
51
03204002
Synchronous negotiation error.
51
03214002
The drive unexpectedly disconnected from the SCSI bus.
51
03224002
Unexpected message.
51
03234002
Unexpected Tag message.
51
03244002
Channel busy.
51
03254002
Message Reject received on a valid message.
51
0326450A
The disk device reported Vendor Unique SCSI Sense Data.
51
03270101
A disk related error code was reported which was unknown to the Fault
Management firmware. Note that in this instance the Associated
Additional Sense Code and Associated Additional Sense Code Qualifier
fields are undefined.
41
0328450A
The disk device reported standard SCSI Sense Data.
51
03324002
SCSI bus selection timeout.
Pass-through
03330002
Device power on reset.
Pass-through
03344002
Target assertion of REQ after WAIT DISCONNECT.
Pass-through
03354002
During device initialization a Test Unit Ready command or a Read
Capacity command to the device failed.
Pass-through
03364002
During device initialization the device reported a deferred error.
Pass-through
Table D–1
Instance Codes (Continued)
Instance
Code
Description
Template