B–78

HSG80 User’s Guide

Not all devices have a device fault LED. Therefore, they do not appear
to respond to the LOCATE command.

UNITS
Causes the green device fault LEDs of all devices used by the units to
flash. This command is useful to determine which devices are not
currently configured into logical units. Enter LOCATE CANCEL to
turn off the device fault LEDs.

container-name
Causes the green device fault LEDs on the devices within the
container-name to flash. If a device name is given, the device’s fault
LED is turned on. If a storageset name is given, the fault LED on all of
the devices assigned to the storageset turns on. Use LOCATE CANCEL
to turn off the LEDs.

unit-number
Causes the green device fault LEDs on the devices making up the unit-
number
to flash. Use LOCATE CANCEL to turn off the LEDs.

Examples

This example shows how to cause the green device fault LED on device
DISK10000 to flash:

LOCATE DISK10000
LOCATE CANCEL

This example shows how to cause the device fault LEDs on all of the
devices assigned to disk unit number D102 to flash:

LOCATE D102

This example shows how to cause the device fault LEDs on all
configured disk devices to flash:

LOCATE DISKS

This example shows how to turn off the flashing device fault LEDs on
all devices:

LOCATE CANCEL