The device specified in the Device Locator has transitioned from
Copying or Normalizing state to Normal state.

51

022E0064

The device specified in the Device Locator field has been converted to a
Mirrorset associated with the logical unit.

51

022F0064

The mirrored device specified in the Device Locator field has been
converted to a single device associated with the logical unit.

51

02383A01

The CACHEB0 Memory Controller, which resides on the other cache
module failed testing performed by the Cache Diagnostics. This is the
mirrored cache Memory Controller. The Memory Address field contains
the starting physical address of the CACHEB0 memory.

14

02392201

Both the CACHEB0 Memory Controller and CACHEB1 Memory
Controller, which resides on the other cache module, failed testing
performed by the Cache Diagnostics. Data cannot be accessed in the
primary cache or the mirror cache. The Memory Address field contains
the starting physical address of the CACHEA0 memory.

14

023E2401

Metadata residing in the controller and on the two cache modules
disagree as to the mirror node. Note that in this instance the Memory
Address, Byte Count, FX Chip register, Memory Controller register, and
Diagnostic register fields are undefined.

14

023F2301

The cache backup battery covering the mirror cache is insufficiently
charged. The Memory Address field contains the starting physical
address of the CACHEB1 memory.

12

02402301

The cache backup battery covering the mirror cache has been declared
bad. Either it failed testing performed by the Cache Diagnostics during
system startup or it was low (insufficiently charged) for longer than the
expected duration. The Memory Address field contains the starting
physical address of the CACHEB1 memory.

12

02412401

Mirrored cache writes have been disabled. Either the primary or the
mirror cache has been declared bad or data invalid and will not be used.
Note that in this instance the Memory Address, Byte Count, FX Chip
register, Memory Controller register, and Diagnostic register fields are
undefined.

14

02422464

Cache failover attempt failed because the other cache was illegally
configured with DIMMs. Note that in this instance the Memory Address,
Byte Count, FX Chip register, Memory Controller register, and
Diagnostic register fields are undefined.

14