HSG80 User’s Guide

This example shows how to display a complete listing of the mirrorset
named MIRR1:

SHOW MIRR1

Name Storageset Uses Used by

------------------------------------------------------------------------------

MIRR1 mirrorset DISK50300 S0

DISK60300

Switches:

POLICY (for replacement) = BEST_PERFORMANCE

COPY (priority) = NORMAL

READ_SOURCE = LEAST_BUSY

MEMBERSHIP = 2, 2 members present

State:

NORMAL

DISK60300 (member 0) is NORMAL

DISK50300 (member 1) is NORMAL

Size: 17769177 blocks

This example shows the full information for a controller:

SHOW THIS_CONTROLLER FULL

Controller:

HSG80 (C) DEC ZG74100120 Software R052G-0, Hardware 0000

NODE_ID = 5000-1FE1-FF00-00B0

ALLOCATION_CLASS = 0SCSI_VERSION = SCSI-2

Not configured for dual-redundancy

Device Port SCSI address 7

TIME: NOT SET

Host PORT_1:

Reported PORT_ID = 5000-1FE1-FF00-00B1

PORT_1_PROFILE = PLDA

PORT_1_TOPOLOGY = LOOP_SOFT (loop up)

PORT_1_AL_PA = 01 (negotiated)

Host PORT_2:

Reported PORT_ID = 5000-1FE1-FF00-00B2

PORT_2_PROFILE = PLDA

PORT_2_TOPOLOGY = LOOP_SOFT (loop up)

PORT_2_AL_PA = 02 (negotiated)

Cache:

256 megabyte write cache, version 0012

Cache is GOOD

No unflushed data in cache

CACHE_FLUSH_TIMER = DEFAULT (10 seconds)

NOCACHE_UPS

Mirrored Cache:

Not enabled

Battery:

MORE THAN 50% CHARGED

Standby capacity: Less than one hour

Time to full charge: 31 hours

Expires: 23-AUG-1957

WARNING: BATTERY AT END OF LIFE WITHIN ONE WEEK, REPLACE BATTERY SOON!