HP Array Controller HSG V8.7 Software User Manual
Page 418

B–146
HSG80 User’s Guide
This example shows how to display a complete listing of the mirrorset
named MIRR1:
SHOW MIRR1
Name Storageset Uses Used by
------------------------------------------------------------------------------
MIRR1 mirrorset DISK50300 S0
DISK60300
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
COPY (priority) = NORMAL
READ_SOURCE = LEAST_BUSY
MEMBERSHIP = 2, 2 members present
State:
NORMAL
DISK60300 (member 0) is NORMAL
DISK50300 (member 1) is NORMAL
Size: 17769177 blocks
This example shows the full information for a controller:
SHOW THIS_CONTROLLER FULL
Controller:
HSG80 (C) DEC ZG74100120 Software R052G-0, Hardware 0000
NODE_ID = 5000-1FE1-FF00-00B0
ALLOCATION_CLASS = 0SCSI_VERSION = SCSI-2
Not configured for dual-redundancy
Device Port SCSI address 7
TIME: NOT SET
Host PORT_1:
Reported PORT_ID = 5000-1FE1-FF00-00B1
PORT_1_PROFILE = PLDA
PORT_1_TOPOLOGY = LOOP_SOFT (loop up)
PORT_1_AL_PA = 01 (negotiated)
Host PORT_2:
Reported PORT_ID = 5000-1FE1-FF00-00B2
PORT_2_PROFILE = PLDA
PORT_2_TOPOLOGY = LOOP_SOFT (loop up)
PORT_2_AL_PA = 02 (negotiated)
Cache:
256 megabyte write cache, version 0012
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
NOCACHE_UPS
Mirrored Cache:
Not enabled
Battery:
MORE THAN 50% CHARGED
Standby capacity: Less than one hour
Time to full charge: 31 hours
Expires: 23-AUG-1957
WARNING: BATTERY AT END OF LIFE WITHIN ONE WEEK, REPLACE BATTERY SOON!