beautypg.com

HP Array Controller HSG V8.7 Software User Manual

Page 367

background image

CLI Commands

B–95

RUN

Runs a diagnostic or utility program on “this controller.” Diagnostic
and utility programs only run on “this controller.”

Syntax

RUN program-name

Parameter

program-name
The program-name parameter specifies the name of the diagnostic or
utility program to be run. The following programs can currently be run:

n

CHVSN—This is not a user utility. This utility may be used by
DIGITAL authorized service personnel only.

n

CLCP—A utility used to load updated software code or patches.
See “Using CLCP to Install, Delete, and List Software Patches,”
page 6–6 fo
r more information regarding this utility.

n

CLONE—A utility used to automate the process of mirroring units
to create a snapshot copy of host unit data. See “Cloning Data for
Backup,” page 3–19,
for more information regarding this utility.

n

CONFIG—A utility used to locate and add devices to the controller
configuration. CONFIG may be run anytime new devices are added
to the subsystem. See “Adding Several Disk Drives at a Time,” page
3–55 for m
ore information regarding this utility.

n

DILX—A utility used to test and verify the controller’s operation
with attached storage devices under a high or low I/O load. Run
DILX (disk inline exerciser) only when there is no activity on the
controller. The total I/O load is handled by the controller, bypassing
the host.

The DILX utility has two modes, an autoconfigure mode, and a
standard mode.

Caution Run the DILX utility in the autoconfigure mode only at initial
installations. When write operations are enabled, the DILX utility may
overwrite existing data.