Event Reporting: Templates and Codes

D–43

01950188

An error has occurred that caused the FX to be rest, when not permissible.

n

Last Failure Parameter [0] contains the value of read diagnostic register 0.

n

Last Failure Parameter [1] contains the value of read diagnostic register 1.

n

Last Failure Parameter [2] contains the value of write diagnostic register 0.

n

Last Failure Parameter [3] contains the value of write diagnostic register 1.

n

Last Failure Parameter [4] contains the IBUS address of error register.

n

Last Failure Parameter [5] contains the PCFX PDAL control / status register.

n

Last Failure Parameter [6] contains the PCFX CDAL control / status register.

n

Last Failure Parameter [7] contains the current PDAL address of error register.

01960186

The Ibus is inaccessible.

n

Last Failure Parameter [0] contains the value of read diagnostic register 0.

n

Last Failure Parameter [1] contains the value of read diagnostic register 1.

n

Last Failure Parameter [2] contains the value of read diagnostic register 2.

n

Last Failure Parameter [3] contains the value of write diagnostic register 0.

n

Last Failure Parameter [4] contains the value of write diagnostic register 1.

n

Last Failure Parameter [5] contains the IBUS address of error register.

01970188

Software indicates all NMI causes cleared, but some remain.

n

Last Failure Parameter [0] contains the value of read diagnostic register 0.

n

Last Failure Parameter [1] contains the value of read diagnostic register 1.

n

Last Failure Parameter [2] contains the value of read diagnostic register 2.

n

Last Failure Parameter [3] contains the value of write diagnostic register 0.

n

Last Failure Parameter [4] contains the value of write diagnostic register 1.

n

Last Failure Parameter [5] contains the IBUS address of error register.

n

Last Failure Parameter [6] contains the PCFX PDAL control / status register.

n

Last Failure Parameter [7] contains the PCFX CDAL control / status register.

01982087

The Ibus encountered a parity error.

n

Last Failure Parameter [0] contains the value of read diagnostic register 0.

n

Last Failure Parameter [1] contains the value of read diagnostic register 1.

n

Last Failure Parameter [2] contains the value of read diagnostic register 2.

n

Last Failure Parameter [3] contains the value of write diagnostic register 0.

n

Last Failure Parameter [4] contains the value of write diagnostic register 1.

n

Last Failure Parameter [5] contains the IBUS address of error register.

n

Last Failure Parameter [6] contains the RIP.

Table D–3

Last Failure Codes (Continued)

Code

Description