Table b–3 poweroff switch settings – HP Array Controller HSG V8.7 Software User Manual

Page 356

background image

B–84

HSG80 User’s Guide

Table B–3 shows what action will be taken depending on the switch
settings and the results of the attempted flush:

Table B–3 POWEROFF Switch Settings

In dual-redundant mode, if both controllers can’t be shutdown, then
both controllers and their batteries’ chargers remain on.

Example

This example shows how to power off the disk units and the cabinet in
10 seconds (BATTERY_OFF and NO_OVERRIDE_BAD_FLUSH are
the defaults):

POWEROFF SECONDS=10

Battery Switch

Override Switch

Flush
Results

Action

BATTERY_ON

OVERRIDE_BAD_FLUSH

Success

Controller and units in cabinet
shutdown, ECB charger remains on.

BATTERY_ON

OVERRIDE_BAD_FLUSH

Failure

Controller and units in cabinet
shutdown, ECB charger remains on.

BATTERY_ON

NO_OVERRIDE_BAD_FLUSH Success

Controller and units in cabinet
shutdown, ECB charger remains on.

BATTERY_ON

NO_OVERRIDE_BAD_FLUSH Failure

Nothing is shutdown, ECB charger
remains on, user is notified of a bad
flush.

BATTERY_OFF

OVERRIDE_BAD_FLUSH

Success

Controller and units in cabinet
shutdown, ECB charger turned off.

BATTERY_OFF

OVERRIDE_BAD_FLUSH

Failure

Controller and units in cabinet
shutdown, ECB charger turned off.

BATTERY_OFF

NO_OVERRIDE_BAD_FLUSH Success

Controller and units in cabinet
shutdown, ECB charger turned off.

BATTERY_OFF

NO_OVERRIDE_BAD_FLUSH Failure

Nothing is shutdown, ECB charger
remains on, user is notified of a bad
flush.