Table d–3 last failure codes (continued), Component ids – HP Array Controller HSG V8.7 Software User Manual

Page 472

background image

D–38

HSG80 User’s Guide

Component IDs

A component ID uniquely identifies the software component that
detected the event and is found at byte offset {11}35 (see “Component
Identifier Codes,” page D–82
).

Table D–3 contains the last failure codes that can be issued by the
controller’s fault-management software.

Table D–3

Last Failure Codes

Code

Description

01000100

Memory allocation failure during executive initialization.

01010100

An interrupt without any handler was triggered.

01020100

Entry on timer queue was not of type AQ or BQ.

01030100

Memory allocation for a facility lock failed.

01040100

Memory initialization called with invalid memory type.

01082004

The core diagnostics reported a fault.

n

Last Failure Parameter[0] contains the error code value (same as blinking OCP
LEDs error code).

n

Last Failure Parameter[1] contains the address of the fault.

n

Last Failure Parameter[2] contains the actual data value.

n

Last Failure Parameter[3] contains the expected data value.

01090105

n

An NMI occurred during EXEC$BUGCHECK processing.

n

Last Failure Parameter[0] contains the executive flags value.

n

Last Failure Parameter[1] contains the RIP from the NMI stack.

n

Last Failure Parameter[2] contains the read diagnostic register 0 value.

n

Last Failure Parameter[3] contains the FX Chip CSR value.

n

Last Failure Parameter[4] contains the SIP last failure code value

010D0110

The System Information structure within the System Information Page has been reset to
default settings. The only known cause for this event is an I960 processor hang caused
by a reference to a memory region that is not implemented. When such a hang occurs,
controller modules equipped with inactivity watchdog timer circuitry will
spontaneously reboot after the watchdog timer expires (within seconds of the hang).
Controller modules not so equipped will just hang as indicated by the green LED on the
OCP remaining in a steady state.