Replacement Procedures

5–37

4. Start FRUTIL with the following command:

RUN FRUTIL

FRUTIL displays the following:

Do you intend to replace this controller’s cache battery? Y/N

5. Enter N(o). FRUTIL displays the FRUTIL Main menu:

FRUTIL Main Menu:

1. Replace or remove a controller or cache module

2. Install a controller or cache module

3. Replace a PVA module

4. Replace an I/O module

5. Exit

Enter choice: 1, 2, 3, 4, or 5 ->

6. Enter option 3, Replace a PVA module from the FRUTIL Main menu.

FRUTIL displays the PVA Replacement menu:

FRUTIL PVA Replacement Menu:

1. Master Enclosure (ID 0)

2. First Expansion Enclosure (ID 2)

3. Second Expansion Enclosure (ID 3)

4. Exit

Enter Choice: 1, 2, 3, or 4 ->

Note The HSG80 controller can support up to three enclosures. The
FRUTIL PVA Replacement menu has options for three enclosures
regardless of how many enclosures are connected.

7. Enter option 2, First Expansion Enclosure (ID 2), to replace the PVA in

the first expansion enclosure or option 3, Second Expansion Enclosure
(ID 3)
to replace the PVA in the second expansion enclosure from the
FRUTIL PVA Replacement menu. FRUTIL displays the following:

Do you have a replacement PVA module? Y/N

8. Enter Y(es) and press return. FRUTIL displays the following:

Ensure the replacement PVA’s address is set to 2 [or 3].

Press return to quiesce device port activity.

9. Set the replacement PVA’s address to 2 for the first expansion enclosure

or to 3 for the second expansion enclosure.