Switches, Examples – HP Array Controller HSG V8.7 Software User Manual
Page 417
CLI Commands
B–145
1234 5678 9ABC EF00 0001 0001 3056 00D2
Each single disk unit or storage device in your subsystem is assigned a
unique unit ID number. The controller constructs a unit ID number for
each device you add to the subsystem. The ID number consists of the
controller’s worldwide node ID and a unique, internally generated
serial stamp. You cannot set or change unit ID numbers.
Unit ID numbers stay with the unit when you move the unit from one
slot to another in the enclosure.
Switches
FULL
Displays additional information about each device, storageset, or
controller.
Examples
This example shows how to display a listing of disks:
SHOW DISKS
Name Type Port Targ Lun Used by
-----------------------------------------------------------
DISK20300 disk 100 D100
DISK10100 disk 1 1 0 D101
This example shows a full listing of devices attached to the controller:
SHOW DEVICES FULL
Name Type Port Targ Lun Used by
------------------------------------------------------------------------------
DISK10300 disk 1 3 0 R0
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = ASYNCHRONOUS (ASYNCHRONOUS negotiated)
Size: 8378028 blocks
DISK20100 disk 2 01 0 S0
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = ASYNCHRONOUS (ASYNCHRONOUS negotiated)
Size: 8377528 blocks
Configuration being backed up on this container