Configuring a mirrorset, Configuring a mirrorset –56, Example – HP Array Controller HSG V8.7 Software User Manual
Page 134
3–56
HSG80 User’s Guide
3. Present the stripeset to the host by giving it a unit number the host can
recognize. Optionally, you can append Unit switch values. If you do not
specify switch values, the default values are applied.
ADD UNIT
unit-number stripeset-name switch
4. Verify the stripeset configuration and switches. Use the following
command:
SHOW
stripeset-name
5. Verify the unit configuration and switches. Use the following command:
SHOW
unit-number
Example
The following example shows the commands you would use to create
Stripe1, a three-member stripeset:
ADD STRIPESET STRIPE1 DISK10000 DISK20000 DISK30000
INITIALIZE STRIPE1 CHUNKSIZE=128
ADD UNIT D100 STRIPE1 MAXIMUM_CACHED_TRANSFER=16
SHOW STRIPE1
SHOW D100
See Appendix B, “CLI Commands,”for more information on stripeset
switches and values.
Configuring a Mirrorset
See Chapter 3, “Creating Storagesets,” for information about creating a
profile and understanding the switches you can set for this kind of
storage unit.
To configure a mirrorset:
1. Create the mirrorset by adding its name to the controller’s list of
storagesets and specifying the disk drives it contains. Optionally, you
can append Mirrorset switch values. If you do not specify switch values,
the default values are applied.
Use the following command to create a mirrorset:
ADD MIRRORSET
mirrorset-name
DISK
nnnnn
DISK
nnnnn switch