Brocade Mobility 7131 Access Point Product Reference Guide (Supporting software release 4.4.0.0 and later) User Manual

Page 52

background image

40

Brocade Mobility 7131 Access Point Product Reference Guide

53-1002517-01

2

2. Tape the template to the wall mounting surface.

If the installation requires the antenna be positioned vertically, the centerline reference (of
the template) needs to be positioned vertically. The cabling shall exit the access point in a
vertical direction.

If the installation requires the antenna be positioned horizontally, the vertical centerline
(of the template) needs to be positioned horizontally. The cabling shall exit the access
point in a horizontal direction.

3. At mounting targets A and B, mark the mounting surface through the template at the target

center.

4. Discard the mounting template.

5. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting

screw and stop when there is 1mm between the screw head and the wall.

If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going
directly into the wall and 6mm (0.23in.) if wall anchors are being used.

6. If required, install and attach a security cable to the access point’s lock port.

7. Attach the antennas to their correct connectors.

For more information on available antennas, see Antenna Options on page 2-33.

8. Place the large center opening of each of the mount slots over the screw heads.

9. Slide the access point down along the mounting surface to hang the mount slots on the screw

heads.

CAUTION

Ensure you are placing the antennas on the correct connectors (depending on your single or
dual-radio model and frequency used) to ensure the successful operation of the access point.

NOTE

It is recommended the access point be mounted with the RJ45 cable connector oriented upwards
or downwards to ensure proper operation.

10. Cable the access point using either the Power Injector solution or an approved line cord and

power supply.

For Power Injector installations:

a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host)

and the Power Injector Data In connector.

b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data &

Power Out connector and the access point’s GE1/POE port.

c. Ensure the cable length from the Ethernet source to the Power Injector and access point

does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The
Power Injector receives power as soon as AC power is applied. For more information on
using the Power Injector, see Power Injector System on page 2-35.

For standard 48-Volt Power Adapter (Part No. 50-14000-247R) and line cord installations: