Electrical characteristics, Mobility 7131 access point radio characteristics – Brocade Mobility 7131 Access Point Product Reference Guide (Supporting software release 4.4.0.0 and later) User Manual
Page 502
![background image](/manuals/361705/502/background.png)
490
Brocade Mobility 7131 Access Point Product Reference Guide
53-1002517-01
A
Electrical Characteristics
The Mobility 7131 Access Point and Mobility 7131N model access points have the following
electrical characteristics:
Mobility 7131 Access Point Radio Characteristics
A Mobility 7131 Access Point has the following radio characteristics:
Storage Temperature
-40°F to 158°F/-40°C to 70°C
Altitude
8000 ft./2438 m @ 82°F/28°C (Operating)
15000 ft./4572 m @ 53°F/12°C (Storage)
Humidity
5 to 95% RH non-condensing
Electrostatic Discharge 15kV air, 8kV contact
Operating Voltage
38-54V DC
Operating Current
Not to exceed 600mA @ 48VDC
Operating Channels
All channels from 4920 MHz to 5825 MHz except channel
52 -64
Channels 1-13 (EU), Channels 1-11 (US/Canada)
Channel 14 (2484 MHz) Japan only
Actual operating frequencies depend on regulatory
Data Rates Supported 802.11g: 1,2,5.5,11,6,9,12,18,24,36,48, and 54Mbps
802.11a: 6,9,12,18,24,36,48, and 54Mbps
802.11n: MCS 0-15 up to 300Mbps
Wireless Medium
Direct Sequence Spread Spectrum (DSSS),
Orthogonal Frequency Division Multiplexing (OFDM)
Spatial multiplexing (MIMO)
Network Standards
802.11a, 802.11b, 802.11g, 802.3, 802.11n (Draft 2.0)
Maximum Available
Transmit Power
20dBm
Transmit Power
Adjustment
1dB increments
Antenna Configuration 2x3 or 3x3