Bus condition – Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual
Page 87
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
85
SAS/SATA Software Menus and Toolbars
Teledyne LeCroy
"Start Events" starts the timer in Timeout Trigger and "End Events" triggers the analyzer (if
first trigger mode is selected) or resets the trigger (if second trigger mode is selected).
Repetitions of the Start Events are ignored until the End Event is encountered or the timer
expires.
Select a pattern for Start Events or End Events, enter a Timeout value, then select Trigger
Mode:
If End Events occur before timer expires
If timer expires before End Events
Note:
Timeouts can only be configured from the Timeout Pattern dialog. The Timeout Pattern dialog
allows configuring other patterns as triggers in combination with timeouts. Other pattern dialogs
do not allow configuration of timeouts.
External/Manual Trigger
To set up an external or manual trigger click the External/Manual Trigger category.
Figure 2.42: External/Manual Trigger Dialog
Device Sleep
To set up Device Sleep click the Device Sleep category. Select Rising Edge or Falling Edge.
Figure 2.43: Device Sleep Dialog
Bus Condition
Double‐click Bus Condition in the Patterns window of the Capture Project dialog to open
the Bus Conditions dialog (see