Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual
Page 455
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
451
Sierra Trainer Generation Language
Teledyne LeCroy
SAS Speed Negotiation Settings
OOB_SAS_Align1_Time
81920
ALIGN(1) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(1) primitives.
OOB_SAS_Align0_Time
81920
ALIGN(0) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(0) primitives.
OOB_SAS_Interspeed_Time 750000
Interspeed time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
OOB_SpeedNeg_MTT.
29998080
OOBI
The maximum time in OOBI during which training
phase of speed negotiation should be completed in
Train‐SNW.
OOB_SpeedNeg_SNTT.
2200
OOBI
The time in OOBI during which generator transmits
phy capability bits in SNW‐3. In Automatic
connection This value is also used for the time during
which generator sends Align0 and Align1 in SNW1
and SNW2.
OOB_SpeedNeg_BCT.
2200
OOBI
The time in OOBI during which generator transmits
COMWAKE or D.C. idle during SNW‐3.
Setting
Default
Value
Description