Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
COMWAKE Settings
COMWAKE_NegLen
280
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst‐Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMWAKE_IdleLen
160
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMWAKE_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMWAKE_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
COMSAS Settings
COMSAS_NegLen
2400
The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst‐Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.
COMSAS_IdleLen
1440
Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.
COMSAS_BurstLen
160
Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.
COMSAS_NumBursts
6
Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
SATA Link Init Settings
OOB_SATA_D102_Time
100000
D10.2 time for SATA link synchronization in
OOBIs.During the specified period, the generator will
transmit D10.2 symbols.
OOB_SATA_Align_Time
100000
ALIGN(0) time for SATA link synchronization in
OOBIs.During the specified period, the generator will
transmit ALIGN(0) primitives.
Setting
Default
Value
Description