beautypg.com

Soft reset (sata only), Sequential trigger mode – Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual

Page 103

background image

    

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

101

SAS/SATA Software Menus and Toolbars

Teledyne LeCroy

Soft Reset (SATA only)

Double‐click Soft Reset to open the Soft Reset dialog.

Figure 2.65: SATA: Soft Reset Dialog

SAS vs. SATA: Not available in SAS.

Sequential Trigger Mode

In the Sequential Trigger mode, triggering occurs whenever the system detects a specific
sequence of patterns. The order of the triggering patterns can be defined. You must
define at least two patterns to enable the selection of the sequential trigger mode.

Note:

Primitives and Symbols or Frames occurring very close together on different ports cause false

triggers to occur.

To define a triggering sequence, select more than one pattern, then check the
Define Sequential Trigger Mode check box.

Figure 2.66: SAS: Select Sequential Trigger Mode

SAS vs. SATA: SATA Dialog has different patterns.