148
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
Delay in sending frame
Check this to delay sending frame and enter a value for the delay.
Frame Length Error
Check Frame Length Error and choose the type of error to introduce.
Code violation and Disparity error
Check these and specify DWORD offset and number of error DWORDs.
Additionally check:
No WTRM
Code Violation on SATA primitive
Disparity error on SATA primitive
Ignore XRDY/RRDY sequence
Delay in HOLD response (in sending HOLDA)
SOF, EOF and CRC errors
Check these and specify Double or Omit by checking the corresponding option button.
Insert Primitive
Check Insert Primitive and then click the Type button to open the Primitive Type dialog
and select the primitive type.
Figure 2.135: Primitive Type Dialog
Click the down arrow on the Primitive combo box, choose a primitive, then click OK.
Fill reserved fields with
Enter a value for which reserved fields to change, if other than 0.
Field of Frame
Select Destroy, scroll through the available choices in the Field of Frame list box, and
choose a field to destroy. Alternatively, select Specify Value to fill the chosen field with a
pre‐defined value.
Insert Frame
Check Insert Frame, click the down arrow on the Type combo box, and choose the frame
type.Then choose to insert it before or after an outgoing frame command. Make sure that
you have clicked More.