Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

307

Preferences

Teledyne LeCroy

3.18.2

Trace Viewer Tab

Figure 3.131: Preferences Dialog Trace Viewer Tab

Open Trace file In

Default Workspace: The software opens a

trace

file in view(s) based on the specified

default workspace.

As previously saved: The software opens a trace file in view (views) based on the last
saved configuration for the

trace

file.

Optimization

Sampling memory usage optimization: Enables memory cascading for two ports. The
analyzer will use memory of another port if there is not data on another port. (see

“Sampling Memory Usage Optimization” on page 312

)

Quick View: Quick View allows full access to the whole trace more quickly, especially
when using a Gigabit Ethernet connection. However, the trace is NOT written to the host
machine’s hard drive. To save the trace, you must manually click Save.
If you do not check Quick View, the trace loads more slowly but is automatically saved to
the host machine’s hard drive.