Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
305
Preferences
Teledyne LeCroy
3.18.1
General Tab
Figure 3.130: Preferences Dialog General Tab
Paths
User Path specifies the “User” folder path, used by the software after launching the Open
dialog.
Template Files
Protocol Analyzer: You can use a pre‐saved analyzer and/or analyzer/emulator project file
as a template. Whenever you make a new project file, the software uses the template to
initialize the project file.
New Protocol Analyzer Project in Advanced Mode: When you use the New menu item to
create a new project file, the software switches to Advanced mode automatically.
Other
Default Workspace specifies the default workspace file for opening a sample file. You can
save any viewer configuration as a workspace and then specify it as the default
workspace. The software always open a trace file based on the default workspace file.
NCQ Commands Time out Threshold: The software uses this setting in the statistical ATA
command page for NCQ commands. If the time out exceeds this setting, the software
reports an error.