Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual
Page 147
![background image](/manuals/353618/147/background.png)
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
145
Emulation
Teledyne LeCroy
Connection Rate
Select the Connection Rate to allow a higher speed port to communicate with a lower
speed port: Physical Rate, 1.5 G, 3, or 6.
Trigger Source
Click the down arrow on the Trigger Source combo box to choose trigger type:
Immediate, Wait for external trig, or Wait for Analyzer trig.
External Trigger Out
Click the down arrow on the External Trigger out combo box to choose the external
trigger level: High, Low, or No change on command execution.
Retry
Enter a value for the number of command retries when a command failed in the Retry
text box.
Store Payload in Buffer
Check the Store Payload in Buffer check box and enter values for Data Offset and Data
Length.
Auto Update LBA
Check the Auto Update LBA check box and check an auto update option button.
Send Hard Reset
Check the radio button and enter the delay after command restarts to send the Hard
Reset.
LBA Overlay - Overwrites first Dword of:
Check the LBA Overlay ‐ Overwrites first Dword of check box. Select one of the two
options:
Each sector with: Overwrites first Dword of each sector with given value
First sector with: Overwrites first Dword of first sector with given value band
increments for next sector(s)
Random Error Injection
Random Error Injection specifies the probability of Error Injection on the command. The
probability percentage that you select applies to all Error Injection items.
Close Connection Setting
Checking Close Connection Setting enables the Error Settings button. Click this button to
display the Close Connection Setting dialog (see