Teledyne LeCroy

Target and Device Emulation

188

 

 

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

Figure 2.180: SAS: Identify Error Setting Dialog

Sending Identify Frame

Check the Send option button, then specify the number of Identify frames to send (and a
delay, if needed). 
Not to send Identify frames, check the Do not send identify frames option button.

Frame Type Error

Check this to send a Frame Type error.

Frame Length Error

Check Frame Length error and enter the number of DWORDs in the corresponding text
box.

SOAF, EOAF and CRC

Check any or all and check the criteria for introduction.

Code violation and Disparity

Check either or both and specify DWORD offset and Number of DWORDs in the
corresponding text boxes.

2.6.3

Connection Management (SAS only)

Click the Connection Management icon in the Errors window to display the Connection
Management Setting dialog (see

Figure 2.181 on page 187

).