Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual
Page 453

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
449
Sierra Trainer Generation Language
Teledyne LeCroy
AutoMode Settings
AutoOOBMode
On
When set, the generator will go through the stages of 
bringing up the link automatically, including waiting 
for and responding to the device or host it is 
connected to. 
AutoHoldMode
0
When set, the generator will respond automatically 
to Hold requests. Not supported for version 1.1 
(reserved). 
AutoDMAT
0
When set, the generator will respond automatically 
to DMAT requests. Not supported for version 1.1 
(reserved). 
AutoSpeedNeg
On
When set, the generator will automatically go 
throughthe speed negotiation process, for the speed 
set in the PINTERFACEC_SERDES register for the 
Trainer. 
AutoAlignSATA
0
When set, the generator will automatically inserting 
the stream 2 Align(0) primitives every 254 
DWORD
s, as
specified in the SATA spec.
AutoAlignSAS
On
When set, the generator will automatically inserting 
the stream Align primitives every 2048 
DWORD
s, as
specified in the SAS spec.Two Align modes can be 
turned on simultaneously, to support STP
COMINIT Settings
COMINIT_NegLen
800
The number of bursts to send as part of this OOB 
type.Each Burst is followed by an Idle. The Burst‐Idle 
pairs are repeated the requested number of times, 
and then followed by the Negation_length of Idle. 
COMINIT_IdleLen
480
Burst time between each OOB idle in OOBIs.During 
the specified period, the generator will send 
ALIGN(0) at the specified speed. 
COMINIT_BurstLen
160
Idle time between each OOB burst in OOBIs.During 
the specified period, the generator will keep the line 
at electric idle. 
COMINIT_NumBursts
6
Negation time at the end of the OOB signal in 
OOBIs.During the specified period, the generator will 
keep the line at electric idle. 
Setting
Default 
Value