beautypg.com

Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual

Page 453

background image

    

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

449

Sierra Trainer Generation Language

Teledyne LeCroy

AutoMode Settings
AutoOOBMode

On

When set, the generator will go through the stages of
bringing up the link automatically, including waiting
for and responding to the device or host it is
connected to.

AutoHoldMode

0

When set, the generator will respond automatically
to Hold requests. Not supported for version 1.1
(reserved).

AutoDMAT

0

When set, the generator will respond automatically
to DMAT requests. Not supported for version 1.1
(reserved).

AutoSpeedNeg

On

When set, the generator will automatically go
throughthe speed negotiation process, for the speed
set in the PINTERFACEC_SERDES register for the
Trainer.

AutoAlignSATA

0

When set, the generator will automatically inserting
the stream 2 Align(0) primitives every 254

DWORD

s, as

specified in the SATA spec.

AutoAlignSAS

On

When set, the generator will automatically inserting
the stream Align primitives every 2048

DWORD

s, as

specified in the SAS spec.Two Align modes can be
turned on simultaneously, to support STP

COMINIT Settings
COMINIT_NegLen

800

The number of bursts to send as part of this OOB
type.Each Burst is followed by an Idle. The Burst‐Idle
pairs are repeated the requested number of times,
and then followed by the Negation_length of Idle.

COMINIT_IdleLen

480

Burst time between each OOB idle in OOBIs.During
the specified period, the generator will send
ALIGN(0) at the specified speed.

COMINIT_BurstLen

160

Idle time between each OOB burst in OOBIs.During
the specified period, the generator will keep the line
at electric idle.

COMINIT_NumBursts

6

Negation time at the end of the OOB signal in
OOBIs.During the specified period, the generator will
keep the line at electric idle.

Setting

Default
Value

Description