beautypg.com

1 available resources – Teledyne LeCroy Sierra M6-4 SAS_SATA Protocol Analyzer User Manual User Manual

Page 363

background image

    

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

359

Scenario Actions

Teledyne LeCroy

1

Only shown in Action Properties dialog box when creating a sequence.

4.8.1

Available Resources

You can specify Events, Combined Events and Actions and additional Events. The
application automatically checks for the maximum number of terms (Events/Actions).
When you exceed the limit, an error is flagged, prompting you to jump to the place that
caused the error.

The list of available resources is given below:

External Trigger X 1

Analyzer Trigger X 1

Primitive Detector (each has its own Embedded counter in M12x) X 8

Pattern Detector (each has its own Embedded counter in M12x) X 8 (a total of 12
DWORD detectors are shared between all pattern detectors)

Frame Type Detector X 24

Counter X 12

Timer X 8

OOB X 1

ComWakeDetected X 1

ComWakeCompleted X 1

ComInitDetected X 1

ComInitCompleted X 1

ComSasDetected X 1

ComSasCompleted X 1

Snw1 X 1

Restart

All Sequences

1

Restart all sequences in the scenario.

1

Current Sequence

1

Restart the sequence that contains this action
definition.

1

SNW

Speed Negotiation
Retime

Set RCDT, SNTT, ALT/TLT, TX speed, TRAIN/
TRAIN_DONE pattern, and/or PHY Capability.

Speed Negotiation
Violation

Set Violation Type.

Stop Scenario

Stops all scenario activity.

Substitute Data DWORD

Substitutes a data DWORD in the traffic.

with SAS Primitive

Substitutes a SAS primitive in the traffic.

with SATA Primitive

Substitutes a SATA primitive in the traffic.

Trigger Output

Sends a signal out the trigger port to the device
downstream.
The trigger point in the Analyzer that caused the
analyzer trigger action will not be the selected
event, it will be the selected event with some
offset.

Action

Description