beautypg.com

Fortinet 548B User Manual

Page 953

background image

- 953 -

Non-Configurable Data

Robustness - Enter the robustness value. This variable allows tuning for the expected packet loss
on a subnet. If you expect the subnet to be lossy, you should enter a higher number for this
parameter. MLD is robust to (robustness variable-1) packet losses. Valid values are from (1 to 255) .
The default value is 2

Startup Query Interval - Enter the number of seconds between the transmission of startup queries
on the selected interface. The valid values are from (1 to 300) . The default value is 31.

Startup Query Count - Enter the number of queries to be sent on startup. The valid values are from
(1 to 20) . The default value is 2.

Command Buttons

Submit - Send the updated configuration to the switch. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is performed.

11.9.1.3 Viewing MLD Groups Summary Page

Selection Criteria

Group Address - Indicates the address of the Mgmd members.

Non-Configurable Data

Slot/Port - Indicates the slot and port on which data is displayed.

Last Reporter - The IP Address of the source of the last membership report received for this
multicast group address on the interface.

Up Time - Time elapsed in seconds since the multicast group has been known.

Expiry Time - Time left in seconds before the entry is removed from the MLD membership table of
this interface.

Filter Mode - The filter mode of the multicast group on this interface. The values it can take are
INCLUDE and EXCLUDE.

Version1 Host Timer - The time remaining until the router assumes there are no longer any MLD
version-1 Hosts on the specified interface.

Group Compat Mode - The compatibility mode of the multicast group on the interface. The values it
can take are MLDv1 and MLDv2.