Fortinet 548B User Manual
Page 953
- 953 -
Non-Configurable Data
Robustness - Enter the robustness value. This variable allows tuning for the expected packet loss
on a subnet. If you expect the subnet to be lossy, you should enter a higher number for this
parameter. MLD is robust to (robustness variable-1) packet losses. Valid values are from (1 to 255) .
The default value is 2
Startup Query Interval - Enter the number of seconds between the transmission of startup queries
on the selected interface. The valid values are from (1 to 300) . The default value is 31.
Startup Query Count - Enter the number of queries to be sent on startup. The valid values are from
(1 to 20) . The default value is 2.
Command Buttons
Submit - Send the updated configuration to the switch. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is performed.
11.9.1.3 Viewing MLD Groups Summary Page
Selection Criteria
Group Address - Indicates the address of the Mgmd members.
Non-Configurable Data
Slot/Port - Indicates the slot and port on which data is displayed.
Last Reporter - The IP Address of the source of the last membership report received for this
multicast group address on the interface.
Up Time - Time elapsed in seconds since the multicast group has been known.
Expiry Time - Time left in seconds before the entry is removed from the MLD membership table of
this interface.
Filter Mode - The filter mode of the multicast group on this interface. The values it can take are
INCLUDE and EXCLUDE.
Version1 Host Timer - The time remaining until the router assumes there are no longer any MLD
version-1 Hosts on the specified interface.
Group Compat Mode - The compatibility mode of the multicast group on the interface. The values it
can take are MLDv1 and MLDv2.