beautypg.com

6 ipv6 menu, Ipv6 menu – Fortinet 548B User Manual

Page 861

background image

- 861 -

Configurable Data

SSH Session Timeout (Minutes) - This text field is used to configure the inactivity timeout value for
incoming SSH sessions to the switch. The acceptable range for this value is (1-160) minutes.

Non-Configurable Data

SSH Connections in Use - Displays the number of SSH connections currently in use in the system.

Keys Present - Displays which keys, RSA, DSA or both, are present (if any).

Key Generation Status - Displays which keys, RSA or DSA, are being generated.

Command Buttons

Submit - Send the updated screen to the switch. Changes take effect on the switch but these
changes will not be retained across a power cycle unless a save is performed.

Download Host Keys - Link to the File Transfer page for the Host Key download. Note that to
download SSH key files SSH must be administratively disabled and there can be no active SSH
sessions.

Generate RSA Host Keys - Begin generating the RSA host keys. Note that to generate SSH key
files SSH must be administratively disabled and there can be no active SSH sessions.

Generate DSA Host Key - Begin generating the DSA host keys. Note that to generate SSH key files
SSH must be administratively disabled and there can be no active SSH sessions.

Delete - Use to delete the corresponding key file (RSA or DSA), if it is present.

11.6

IPv6 Menu

11.6.1

Configuring IPv6 Global Configuration Page

Configurable Data

IPv6 Unicast Routing - Globally enable or disable IPv6 unicast routing on the entity.

IPv6 Forwarding - Enable or disable forwarding of IPv6 frames on the router.

Hop Limit - Specifies the TTL value for the router.The valid range is (1 to 255). The Value '0' is used
to set the TTL to deafult value.

ICMPv6 Rate Limit Error Interval - To control the ICMPv6 error packets user can specify the
number of ICMP error packets are allowed per burst interval. By Default Ratelimit is 100 packets/sec
i.e burst interval is 1000 msec. To disable ICMP Ratelimiting set this field to '0'.Valid Rate Interval
must be in the range (0 to 2147483647)