7.3.13.10 set sflow interval

The user can go to the CLI Interface Configuration Mode to set polling interval, use the sflow poller
interval <0-86400>
interface configuration command. Use the no sflow poller interval return to default
value zero.

Syntax

sflow poller interval <0-86400>
no sflow poller interval

Default Setting

0

Command Mode

Interface Config

7.3.13.11 set sflow sampler index

The user can go to the CLI Interface Configuration Mode to configure a new sFlow sampler instance, use
the sflow sampler interface configuration command. Use the no sflow sampler return to
default setting.

Syntax

sflow sampler
no sflow sampler

Default Setting

None

Command Mode

Interface Config

7.3.13.12 set sflow poller index

The user can go to the CLI Interface Configuration Mode to configure a new sFlow poller instance, use
the sflow poller interface configuration command. Use the no sflow poller return to default
setting.

Syntax

sflow poller
no sflow poller