Fortinet 548B User Manual
Page 655
- 655 -
sFlow Receiver Address - The IP address of the sFlow collector.
sFlow Receiver Port - The destination port for sFlow datagrams.
sFlow Receiver Datagram Version - The version of sFlow datagrams that should be sent.
Command Buttons
Submit - Send the updated data to the switch and cause the changes to take effect on the switch.
Refresh - Refresh the data on the screen with present state of data in the switch.
11.2.7.3 Configuring sFlow Poller Configuration Page
sFlow agent collects time-based sampling of network interface statistics and sends them to the
configured sFlow receivers. A data source configured to collect counter samples is called a poller.
Selection Criteria
sFlow Poller Datasource(Slot/Port) - sFlowDataSource for this sFlow sampler. This Agent will
support Physical ports only.
Configurable Data
Receiver Index - The sFlowReceiver associated with this counter poller. Allowed range is (1 to 8 )
Poller Interval - The maximum number of seconds between successive samples of the counters
associated with this data source. A sampling interval of 0 disables counter sampling. Allowed range
is (0 to 86400 secs)
Non-Configurable Data
Slot/Port - The interface for which data is being displayed.
Receiver Index - The sFlowReceiver for this sFlow Counter Poller. If set to 0, the poller
configuration is set to default and the poller is deleted. Only active receivers can be set. If a receiver
expires then all pollers associated with the receiver will also expire. Allowed range is (1 to 8 )
Poller Interval - The maximum number of seconds between successive samples of the counters
associated with this data source.
Command Buttons
Submit - Send the updated data to the switch and cause the changes to take effect on the switch.
Refresh - Refresh the data on the screen with present state of data in the switch.