Interlogix VEREX Director User Manual
Page 66
58
Verex Director V4.9.1 User's Guide
21-0381E v4.9.1
the door for a duration equal to the "extended
unlock duration". This is the same as a user
who is set for "extended unlock/challenged"
gaining entry with an access card or token.
- Pending Unlock: This is an unlock command
that waits for one person to enter the facility at
the specific door.
- Grant Last User -- Reader 1 (or 2): If the last
user at a reader was denied access, this will
issue a 'Momentary Unlocking', and log that
card/user as being granted entry.
Cards can be denied due to being expired, locked
out, wrong time, wrong door class, etc. -- as long as
they are defined in the system.
This feature will be unavailable if someone else is
granted entry, or after 5 minutes from the time the
person was denied access (although they can
simply present their card/token again).
This may be used in conjunction with an event-
triggered camera-view for the door (so a remote
attendant can see the person).
Related Topics: "Initial Set Up of: Views, Maps,
Cameras" (step 3b).
This can also be used in conjunction with the pop-
up "Photo-Verification" feature (if it is set to trigger
on 'Access Denied' events).
Related Topics: Visually Verifying Users (Photo-
Verification)"
This cannot be used (or does not apply) with:
- Cards being enrolled or disabled at a reader set to
do this (although it will apply for cards denied due
to wrong area/time, etc.);
- Access being denied due to door interlock
violations or area/disarm authority issues.
___________________________________________
Input-Point Commands
(After right-clicking a Sensor)
Also See: "Common Commands", previous/above.
-------------------------------------------------------------------------
- Bypass / Remove Bypass: "Bypass" allows
arming an area with a tripped or faulty input
point (sensor). "Remove Bypass" allows
monitoring the input point again (for a sensor
that is "OK").
____________________________________________
Output-Point Commands
(After right-clicking an Output/Device)
Also See: "Common Commands", previous/above.
--------------------------------------------------------------------------
Tips: First, select "Manual Output Control".
Additional parameters appear when applicable
(duration, etc.).
- Normal: No manual control (i.e., return to
normal operation);
- Always: Allows setting the output as On or Off
continuously (until manual control is removed);
- Momentary: Allows setting the output to
pulse/toggle once. Additional selections will
appear for:
Whether it is to be triggered On
(high), or Off (Low);
The state it will be left in
afterwards (Off, On, or Normal);
How long the
relay will remain triggered (1 second to 1 week).
- Duty Cycle (1 sec. On/1 sec. off): The output
will be pulsed on and off continuously for a
selected duration (1 second to 1 week).
___________________________________________
Elevator Commands
(After right-clicking an Elevator)
Also See: "Common Commands", previous/above.
-------------------------------------------------------------------------
- Secure / Desecure: This allows applying or
removing controlled-access for all floors as
accessed from the specific elevator (lift).
(Secure: An access card or token provides access to
specific floors;
Desecure: Anyone can access any
floor without a card or token.
Controlling a Floor (as accessed from all cabs): Refer
to "Checking Status or Controlling Floors"