Interlogix VEREX Director User Manual
Page 290

282
Verex Director V4.9.1 User's Guide
21-0381E v4.9.1
Area
(if event occurs in a specific area):
Area
Function key #0, #1, ...#9
(Pertains to keypad functions keys)
Area On
When the area is fully armed (ON).
Area
Stay 2 (future use)
When the arming level is STAY 2 (future)
Area Stay
1
When the arming level is STAY.
Area
Stay (1 or 2)
When armed to STAY. (Stay 2 = future)
Area Off
When the arming level is OFF
Area Not
On
When the arming level is "Off" or "Stay".
Area Not
Off
When the arming level is "Stay" or "ON".
Area
Alarm
When area is in ALARM. Resets when
point(s) restore or follows siren timeout
(includes pseudos & tampers)
Area Was
In
Alarm
When area WAS IN ALARM. This is only for
input points in alarm e.g. NOT for system
trouble (clears when alarmed areas are
turned off then back on again)
Area
Siren Fire (1 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 1 sec ON/OFF for
FIRE
Area
Siren Fire (2 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 2 sec ON/OFF for
FIRE
Area
Sonalert (E/E tones on Stay)
Follows sonalert, chime & provides Entry/Exit
tones when armed to STAY & ON
Area
Sonalert (No E/E tones on Stay)
Follows sonalert, chime & does not provide
Entry/Exit tones when armed to STAY but
provides Entry/Exit tones in ON
Area
Extended Delay Entry Tones
Follows Garage/extended delay Entry Tones
Area Bypasses
When any point in this area is BYPASSED
Area Fire
When any ‘FIRE’ type point in this area is in
alarm
Area Hold-Up
When any ‘HOLD UP’ type point in this area
is in alarm
Area
Auxiliary Alert
When any ‘AUXILIARY ALERT’ type point in
this area is in alarm.
Area Vault
When any ‘VAULT / SAFE’ type point is in
alarm.
Area Burglary
When any ‘BURGLARY’ type point in this
area is in alarm.
Area Supervisory
When any ‘Supervisory' point is in alarm.
Area Pseudo
When any 'Pseudo' condition is in effect.
Area Walk
Test
Area is in ‘Walk’ or ‘Hold-up’ test.
Area Entry
/
Exit
When area Entry / Exit delay is in progress –
provides a steady output (STAY & ON).
Area Entry
When area Entry delay is in progress -
provides a steady output (STAY & ON).
Area Exit
When area Exit delay is in progress -
provides a steady output (STAY & ON).
Area Ready
When the area is ‘Ready To Arm’ - i.e. all
points are secure.
Area Open
Window
When the active/open window of the area's
schedule is in effect.
Area Closing
When the area schedule is expiring in 15
minutes.
Area Door
Unlocked
Area Door
Locked
Out
Area Door
Held
Open
Area Door
Forced
Area Door
Tamper
Door Tampers (door contact condition: no
EOL resistor etc.)
Area Door
Open
Area Door
Secure
Area
Door Sensor Trouble
Door Sensor Troubles (magnetic bond
sensor not ok)
Area
Panic Token Detected