form)
-Panel (optional): If the tree is not set to
show items on a panel-by-panel basis,
you will be able to select a panel here
(for systems that have more than one).
A "Panel Group" reference may also be
shown here, or you can set the 'tree' to list
configuration topics separately for each
panel. For more information, refer to "Other
Desktop Choices".
Standard
and
Alternate
(for 1
st
& 2
nd
card formats to be used at the
same time)
Two card types can be set up, allowing either
Wiegand / Prox and Magstripe/barcode, or two types of
Wiegand / Prox cards to be used with each specific
panel.
All length values refer to number of characters for
magnetic stripe cards (MS), or number of bits for
Wiegand technology (W).
- Token Format: This allows defining
parameters for the basic card/token types (as
selected for each specific reader).
"Wiegand" pertains to cards/tokens for readers with
Wiegand data-format (Wiegand, Proximity, etc.).
Similarly, "Magstripe" pertains to cards for readers
with magstripe output (magstripe, bar-code, etc.).
-------------------------
- [Wiegand 26]: This automatically sets the card-
format values for the standard 26-bit Type-A
Wiegand format.
- [Wiegand 36]: This automatically sets the card-
format values for the proprietary 36-bit Wiegand
format.
Card Site (Site/System Code)
- Site Required: This enables/disables site code
checking. If selected, cards without one of the
specified site codes will be denied access.
- Site Code 1, 2, 3: If site-code checking is
enabled, only cards encoded with one of these
site codes will be allowed access at this site
(e.g., 0004, 1234, 9999).
- Position: The start position of the site code
(1-40);
- Length: The length of the site code (MS: 1-4;
W: 1-16).
Card Version (Version-Number)
This feature requires
V3.2 panel firmware and
V1.5
door/elevator controller module firmware. For an
additional setting, refer to "AutoUpdate Card Version",
under Special (to follow).
- Version Required: This enables/disables
version number checking (allows fixed-ID cards
to be re-issued if lost or stolen).
- Position: The starting position of the version
number (1-40).
- Length: The length of the version number (MS:
1-2; W: 1-8).
Card ID
- Position: The starting position of card ID
number (1-40);
- Length: The length of card ID number (MS: 4-9;
W: 1-32).
32-Bit Cards: Supported with panel firmware
V3.2,
and door/elevator controller module firmware
V1.5
(prev. 20 bit / 6 digits).
V3.2 panels: MaxID=999999999;
V3.31 Panels:
MaxID=4
294
967
295.
- Bits per Card: The length of the card data in
bits (Wiegand), or characters (magnetic stripe).
This can be up to 40.
- Bits per Character
(magstripe only)
: The number
of bits used to identify each character of data on
a magstripe card (future use; fixed as
4
).
Odd Parity
These settings pertain to odd-parity checking, which
helps to identify card 'misreads'.
- Position: The position of the odd-parity
Configuration System Access
Note: For a system set for intrusion-only (under Account Information),
the "Access" tab will appear as "Token Format".