Programmable output functions – Interlogix VEREX Director User Manual
Page 288

280
Verex Director V4.9.1 User's Guide
21-0381E v4.9.1
Failed to Close: Area schedule expired, & no
one armed the system;
In Window: Schedule active;
Out Window: Schedule expired; Pseudo: Internally
monitored conditions (Ref: Config. System
Equipment);
Version "E": This indicates conditions
pertaining to European monitoring requirements
(requires Director
V4.2).
System
(events pertaining to the specific
main/system panel)
:
System Tone if Module Fail
Fallback sonalert (at control panel) if Module
Bus fails. Provides 1 sec. output every 8 sec.
And activates if there is no operational
keypad in an area with programmed
keypads.
System Ground
Start
Ground Start (can only be used on B004 -
main panel output 4)
System Fully
On
When system is FULLY ON
System Partially
On
When system is PARTIALLY ON (Partially or
Fully On for Europe Version)
System Fully
Off
When system is FULLY OFF
System In
Alarm
When system is IN ALARM - resets when
point(s) restore (includes pseudos &
tampers)
System Siren
Follows ALARM & FIRE siren (steady)
System Siren Fire (1 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 1 sec on/off for FIRE
per Keypad Tone. Exception: If selected for
the siren output (#3 on main panel), this
enables UL fire-cadence: ½ sec on/off three
times, 1sec pause, and repeats.
System Siren Fire (2 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 2 sec on/off for FIRE
System Digital
Trouble
Phone line trouble (follows report delay or
line failure)
System Was
In
Alarm
System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for system
trouble (clears when alarmed areas are
turned off then back on again)
System Bypassed
When there is a point BYPASSED
somewhere in the system
System Fire
When any ‘FIRE’ point is in alarm
System Hold-Up
When any ‘HOLD UP’ point is in alarm
System Auxiliary Alert
When any ‘Aux Alert' point is in alarm
System Vault
When any ‘VAULT / SAFE’ type point is in
alarm
System Burglary
When any ‘'Burglary' point is in alarm.
Delayed burglary for European Version.
System Supervisory
When any ‘Supervisory' point is in alarm.
System Pseudo
When any 'Pseudo' condition is in effect.
System System
Trouble
Pseudo 1 – System Trouble / All type tamper
for European Version.
System Battery
Trouble
Pseudo 2 – Battery Trouble
System AC Failure
Pseudo 3 – AC (Mains) Trouble
System Phone
Line
Trouble
Pseudo 4 – Phone Trouble
System Report
Delay
Pseudo 5 – Report Delay
System Time
Lost
Pseudo 6 – Time Lost
System Time
Changed
Pseudo 7 – Time Change
System Program
Changed
Pseudo 8 – Program Change
System Program
Error
Pseudo 9 – Program Error
System Fuse
Failure
Pseudo 10 – Fuse Failure
Programmable Output Functions