Interlogix VEREX Director User Manual
Page 58

50
Verex Director V4.9.1 User's Guide
21-0381E v4.9.1
- Doors and Input Points (top of the form): This
is where you select the specific door or input-
point pertaining to the guard-tour station being
added or changed;
Area Selections: See "Automatic Area Disarming /
Rearming", to follow / below.
To be available here, the specific areas and devices
must already be defined in the system. As well, guard
tour inputs must be set as a "Custom Point Type" with
the "Preprocess" set as "Guard Tour" (and the "Level"
set as "24 hours"). For details, refer to:
"Doors, Readers, and Related Settings",
"Input Points—Custom Point Types", and
"Input Points—Monitored Sensors", as applicable.
- Minimum Time: The minimum allowable time
for the guard to reach this station (from the
previous one);
- Maximum Time: The maximum allowable time
for the guard to reach this station (from the
previous one);
Note: For the 1
st
station (i.e., the "Start Point"
selected under "Guard Tour Monitor"), the time is from
when the guard tour is activated (i.e., when the guard
tour is 'added' to the Guard-Tour monitor screen).
-------------------------
Automatic Area Disarming / Rearming
If you select an area instead of a door or input
point, this allows setting that area to disarm or
rearm automatically when the guard accesses
the preceding station within the allowed time.
- Arming Level: For an area selection, this
provides area arm/disarm choices. Note: "Arm
to Stay" will occur only if the area is disarmed
(Off); "Disarm to Stay" will occur only if the area
is fully armed (On).
- Arming Option: For an area selection, this sets
the type of arming (i.e., whether or not any
sensors (points) that are not 'OK' will be
automatically bypassed to allow the arming to
occur).
Guard Tours [Select Station]
(or [Edit] )