beautypg.com

Panel connection overview, Welcome, Steps – Interlogix VEREX Director User Manual

Page 329: Connections supported

background image

21-0381E v4.9.1

Welcome Report Control Admin Sys

Config

Tech-Ref

321

Welcome

The following is a quick outline of the steps
needed to set up a panel connection. For
details on each step, refer to the indicated
section, and look for headings that apply to
your present task, and type of connection.

Browsing for Topics: You can also browse forward
through the remaining topics, and follow the sections
that pertain to your present task and type of connection.

IP Network Connections

Secure / encrypted and regular IP connections are
also supported for panel communications through a
network, or across the internet.

More: "IP Connectivity".

Panel & Software Revisions:

Beginning with V3.20, the VEREX Director software
can connect with panels V2.0 and higher.
Note: Associated panels must be the same rev.
level, and the Director software must typically be
upgraded to the same level or higher.

Steps

1) Install/Setup Modems and/or Direct-

Cable Connections

Ensure the windows "Direct Cable Con-
nections" and/or modems have been set up on
each applicable PC.

IP Connections: This step is not needed for an IP
connection.
For a panel that connects directly (through a cable),
refer to "PC-to-Panel—Direct Connection" in addition to

Panel Connection Overview

Beginning with V4.0 VEREX Director, you can use the Communications Wizard to set up and initiate communications
with a panel. For more information, refer to "New Installation? Try the Wizard!"

Connections Supported

(

V4.4)

Line Type


Comms
Type

HSC

IP or
sec-
ure IP

Bell
103

External
56k
modem

W.W.
modem
(w/o STU) -
xL panels

W.W.
modem (w/
STU)--
xL panels

Parallel STU
only
(xL panels)

Direct cable
connection

Director
initiated
comms
session

-- Yes Yes

4

Yes 2

Yes 5

Yes 5

--

Yes 3

Panel-
initiated
config
upload

-- Yes Yes

4

No / Yes

2

Yes 5

Yes 5

--

--

Panel
initiated to
transmit
events to
Director

-- Yes -- No

/

Yes

2

-- -- -- --

Panel
transmit to
Central
Station

Yes Yes

(SIP)

Yes

1

-- Yes Yes Yes --

1 Bell 103 to central station: Can be used by itself, or as backup to HSC/SIP reporting.
2 External modem connection: Connection (and panel group) must be dedicated to one panel only.

xL (narrow) Mainboards: RS485 only. Dial-out to Director only via IP connection.
ISM Mainboards: For dial-out to director via external modem, the modem connection must be RS232.

3 xL (narrow) mainboards: Direct connection via RS485.

ISM mainboards: Direct connection can be via RS232 (with no support for external modem) or RS485.

4 Max. feature-set 3; (300 users).
5 Max. feature-set 7.