Panel connection overview, Welcome, Steps – Interlogix VEREX Director User Manual
Page 329: Connections supported
21-0381E v4.9.1
Welcome Report Control Admin Sys
Config
Tech-Ref
321
Welcome
The following is a quick outline of the steps
needed to set up a panel connection. For
details on each step, refer to the indicated
section, and look for headings that apply to
your present task, and type of connection.
Browsing for Topics: You can also browse forward
through the remaining topics, and follow the sections
that pertain to your present task and type of connection.
IP Network Connections
Secure / encrypted and regular IP connections are
also supported for panel communications through a
network, or across the internet.
More: "IP Connectivity".
Panel & Software Revisions:
Beginning with V3.20, the VEREX Director software
can connect with panels V2.0 and higher.
Note: Associated panels must be the same rev.
level, and the Director software must typically be
upgraded to the same level or higher.
Steps
1) Install/Setup Modems and/or Direct-
Cable Connections
Ensure the windows "Direct Cable Con-
nections" and/or modems have been set up on
each applicable PC.
IP Connections: This step is not needed for an IP
connection.
For a panel that connects directly (through a cable),
refer to "PC-to-Panel—Direct Connection" in addition to
Panel Connection Overview
Beginning with V4.0 VEREX Director, you can use the Communications Wizard to set up and initiate communications
with a panel. For more information, refer to "New Installation? Try the Wizard!"
Connections Supported
(
V4.4)
Line Type
Comms
Type
HSC
IP or
sec-
ure IP
Bell
103
External
56k
modem
W.W.
modem
(w/o STU) -
xL panels
W.W.
modem (w/
STU)--
xL panels
Parallel STU
only
(xL panels)
Direct cable
connection
Director
initiated
comms
session
-- Yes Yes
4
Yes 2
Yes 5
Yes 5
--
Yes 3
Panel-
initiated
config
upload
-- Yes Yes
4
No / Yes
2
Yes 5
Yes 5
--
--
Panel
initiated to
transmit
events to
Director
-- Yes -- No
/
Yes
2
-- -- -- --
Panel
transmit to
Central
Station
Yes Yes
(SIP)
Yes
1
-- Yes Yes Yes --
1 Bell 103 to central station: Can be used by itself, or as backup to HSC/SIP reporting.
2 External modem connection: Connection (and panel group) must be dedicated to one panel only.
xL (narrow) Mainboards: RS485 only. Dial-out to Director only via IP connection.
ISM Mainboards: For dial-out to director via external modem, the modem connection must be RS232.
3 xL (narrow) mainboards: Direct connection via RS485.
ISM mainboards: Direct connection can be via RS232 (with no support for external modem) or RS485.
4 Max. feature-set 3; (300 users).
5 Max. feature-set 7.