Activity, Card processing – Interlogix VEREX Director User Manual
Page 255

21-0381E v4.9.1
Welcome Report Control Admin
Sys Config
Tech-Ref
247
authorized entrant to disarm the suite-security
system;
- Exit delay: The duration that the monitoring of
'Exit' points will be held/delayed to allow the
user to exit after arming the keypad.
- Extended Point Delay: The duration that the
monitoring of 'Extended-Delay' points will be
held/delayed to allow an authorized entrant to
disarm the keypad.
- Siren Time: This sets the duration for siren
activations for this suite-security keypad.
The Siren Feature: This pertains to keypad inputs
(and panic keys) set to trigger a siren condition—as
signalled by output #1 (must be set to one of the
"Area: Siren Fire" selections--which also sets the
'cadence').
Also see: Inputs , Outputs , and Panic
(to follow), and: "Input Points—Custom Point Types"
- Stay on Fail to Exit: The suite-security
system will be automatically switched to 'Stay'
mode if the user fails to exit after arming (i.e.,
if a door opening is not detected).
- Terminate Exit Delay: The 'exit delay' will be
truncated when the door closes after the user
arms the keypad and exits.
- Require Function Key PIN: Whether or not use
of the keypad function-keys will require a valid
keypad user to be logged in.
Tip: This setting is recommended to help protect
against false alarms.
For details on using the function keys (special
commands) on a suite-security keypad, refer to the
user's guide for the keypad.
To enable function-key authority for a suite occupant,
refer to the "Function Keys" setting under "Authorities
for Users/Entrants".
- Enable Quick Arming: If this is NOT
selected, keypad arming functions will require
entering your PIN (person with appropriate
authority). If this IS selected, the keypad
arming functions will NOT require PIN entry;
- Allow Forced Arm: Whether or not the suite-
security system can be armed while any
sensors are tripped (i.e., Not OK).
- Auto Arm on Door Close: The keypad will arm
automatically when the door is closed. This
would be used only for a separate keypad that
is monitoring a safe/vault or 'valuables' locker.
-------------------------
- Allow Remote Silence: Determines whether or
not authorized operators will be able to silence
this suite keypad using the software (control &
status).
- Allow Remote Arm: Determines whether or
not authorized operators will be able to arm this
suite keypad using the software (control &
status).
- Allow Remote Disarm: Determines whether or
not authorized operators will be able to disarm
this suite keypad using the software (control &
status).
- Backlight Mode
(
V4.4)
: Future Use.
- Superintendent
(
V4.4)
: Causes
system/hardware-related alarms to be indicated
at this suite keypad.
Activity
(
V4.4)
These settings allow enabling and configuring 'activity'
detection for each suite/keypad. This:
Pertains to
custom 'Activity Monitor' input points;
Can include
persons gaining entry at doors/gates;
Can include
detection via input points on the "Entry/Exit Route".
- Timeout: This allows disabling 'activity'
detection for each suite/keypad, or setting the
maximum duration between activity-detections
for it to still be considered 'in effect'. (The status
is reset if activity is not detected for this
duration.)
Notes: Immediate = 1 second. Short durations are
not recommended. This is the only method for
resetting 'activity' status.
- Include EE Route: Whether or not inputs on the
entry/exit route for this suite will be monitored as
well as 'Activity Monitor' inputs;
- Include Doors: Whether or not persons
entering and leaving the area will trigger the
'activity' status as well (i.e., door openings).
- Alarm on No Activity: This causes an alarm to
be generated if a timeout occurs without activity
being detected.
Related Settings / Features:
Configuration Custom Point Type
"Preprocess = Activity Monitor";
Configuration
Output Points Event "Activity detected" (or 'not).
Card Processing
(Future Use.)
- Single Badge Mode: Future Use. Selects an
action to occur automatically (arm, disarm, etc.)
when a card is accepted at a reader associated
with the suite/keypad.