92
Verex Director V4.9.1 User's Guide
21-0381E v4.9.1
Screen Reference
- Security Suite State
(
[Off]
,
[Stay]
,
and
[On]
)
: These buttons show (and
allow changing) the arming level of the
suite/facility: Off (Disarmed); Stay:
(Perimeter Armed); or ON (Fully
armed).
Notes: Since each keypad typically
pertains to a separate, privately-owned
dwelling, any arming changes should
typically be coordinated with the occupant.
Prior to v4.31, these buttons were 'display-
only'. This feature requires panel firmware
4.25, and 'Panel Control & Status'
operator permission.
- Alarms: This area shows any alarms
for the suite/facility (fire, tripped
sensors, or someone tampering with
the keypad). The "Siren Type" is
indicated as well (None, Sonalert,
Siren, or Fire).
-------------------------
- [Silence]
(
V4.31)
: This allows silencing an
alarm for a selected keypad/suite.
-------------------------
- Input Points: This area lists the suite security
keypad's input points, and shows the status of
each one (i.e., whether or not each sensor has
been 'tripped').
Note: The number of input points supported depends
on the type of suit security keypad installed.
- Panic Keys: This area lists the suite security
keypad's panic keys, and shows the status of
each one (i.e., whether or not any panic keys
have been pressed).
Note: The number of panic keys supported depends
on the type of suit security keypad installed. For
example, 2-zone keypads support panic key #1 only
(triggered by pressing
and *).
- Output Points: This area lists the suite security
keypad's outputs, and shows the status of each
one (i.e., whether or not any of the outputs have
been fired).
Note: The number of programmable output points
supported depends on the type of suit security keypad
installed.
-----------------------------------------------------------
- Security Suite (bottom of form): This is where
you select a suite security keypad to view
diagnostic information. This area shows a
reference number assigned by the system, plus
the name/description of the suite/facility as
defined under 'Configuration'.
- Security Suite Information: Information
pertaining to the selected suite
(version number,
maximum and present baud rate, etc.)
.
- Security Suite Status: Various status topics for
the selected keypad.
- Communication Statistics: This shows
information pertaining to the module bus
communications success rate with this device
over a period of time.
- [Refresh Communication Statistics]: This
updates the screen (i.e., rechecks
communications statistics).
- [Reset Communication Statistics]: This
restarts the counters ('i.e., resets the statistics
values to zero).
Control & Status Panel Control & Status
Suite Security
Control & Status Panel Control & Status
Suite Security Diagnostics