Avago Technologies MegaRAID Fast Path Software User Manual
Page 96

Page 96
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 4: WebBIOS Configuration Utility
|
Creating a Storage Configuration
Figure 50:
WebBIOS Virtual Drive Definition Dialog
NOTE: The WebBIOS Configuration Utility shows the maximum available capacity while
creating the RAID 10 drive group. In version 1.03 of the utility, the maximum size of the
RAID 10 drive group is the sum total of the two RAID 1 drive groups. In version 1.1, the
maximum size is the size of the smaller drive group multiplied by 2.
17. Change the virtual drive options from the defaults listed on the dialog as needed.
Here are brief explanations of the virtual drive options:
— RAID Level: The drop-down menu lists the possible RAID levels for the virtual
drive. Select RAID 10.
— Strip Size: The strip size is the portion of a stripe that resides on a single drive in
the drive group. The stripe consists of the data segments that the RAID
controller writes across multiple drives, not including parity drives. For example,
consider a stripe that contains 64 KB of drive space and has 16 KB of data
residing on each drive in the stripe. In this case, the stripe size is 64 KB and the
strip size is 16 KB. You can set the strip size to 8 KB, 16 KB, 32 KB, 64 KB, 128 KB,
256 KB, 512 KB, and 1024 KB. A larger strip size produces higher read
performance. If your computer regularly performs random read requests,
choose a smaller strip size. The default is 64 KB.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e