11 disk spanning – Avago Technologies MegaRAID Fast Path Software User Manual
Page 27

LSI Corporation Confidential
|
July 2011
Page 27
MegaRAID SAS Software User Guide
Chapter 2: Introduction to RAID
|
Components and Features
RAID 5 combines distributed parity with disk striping. If a single drive fails, it can be
rebuilt from the parity and the data on the remaining drives. An example of a RAID 5
drive group is shown in
. RAID 5 uses parity to provide redundancy for one
drive failure without duplicating the contents of entire drives. RAID 6 uses distributed
parity and disk striping, also, but adds a second set of parity data so that it can survive
up to two drive failures.
Figure 5:
Example of Distributed Parity (RAID 5)
2.4.11
Disk Spanning
Disk spanning allows multiple drives to function like one big drive. Spanning
overcomes lack of disk space and simplifies storage management by combining
existing resources or adding relatively inexpensive resources. For example, four 20-GB
drives can be combined to appear to the operating system as a single 80-GB drive.
Spanning alone does not provide reliability or performance enhancements. Spanned
virtual drives must have the same stripe size and must be contiguous. In
, RAID
1 drive groups are turned into a RAID 10 drive group.
NOTE: Make sure that the spans are in different backplanes, so that if one span fails, you
do not lose the whole drive group.
Figure 6:
Example of Disk Spanning
Spanning two contiguous RAID 0 virtual drives does not produce a new RAID level or
add fault tolerance. It does increase the capacity of the virtual drive and improves
performance by doubling the number of spindles.
Segment 1
Segment 7
Segment 2
Segment 8
Segment 3
Segment 9
Segment 4
Segment 10
Segment 5
Parity (6-10)
Parity (11–15)
Parity (1-5)
Segment 6
Note: Parity is distributed across all drives in the drive group.
Segment 12
Segment 15
Segment 11
Segment 14
Segment 13
Segment 19
Segment 25
Segment 20
Segment 23
Segment 18
Segment 21
Segment 16
Segment 22
Segment 17
Parity (21-25)
Parity (26–30)
Parity (16-20)
Segment 24
Segment 30
Segment 27
Segment 29
Segment 26
Segment 28
60 GB
60 GB
Can Be Accessed as
One 120-GB Drive
60 GB
60 GB
Can Be Accessed as
One 120-GB Drive
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e