Avago Technologies MegaRAID Fast Path Software User Manual
Page 287

LSI Corporation Confidential
|
July 2011
Page 287
MegaRAID SAS Software User Guide
Chapter 6: MegaRAID Storage Manager Overview and Installation
|
Installing MegaRAID Storage Manager
NOTE: To shut down the MegaRAID Storage Manager Framework service, run the
svcadm disable -t MSMFramework
.
It is advisable to stop the Monitor service before stopping the MegaRAID Storage
Manager Framework service.
To stop the Monitor service, run svcadm disable -t MSMMonitor.
To start the Framework service, run svcadm enable MSMFramework.
When the service is in maintenance state, run the svcadm clear MSMFramework
command and svcadm clear MSMMonitor command.
To start the monitor service, run svcadm enable MSMMonitor command.
To check the status of the MegaRAID Storage Manager services, run the command svcs
-a | grep -i msm
.
6.4.5
Installing MegaRAID Storage
Manager for Linux Operating System
Follow these steps if you need to install the MegaRAID Storage Manager software on a
system running Red Hat Linux 3.0, 4.0,5.0, 6.0 or SUSE Linux/SLES 9, 10, and 11:
1. Copy the MSM_linux_installer-11.02.00-00.tar.gz file to a temporary
folder.
2. Untar the MSM_linux_installer-11.02.00-00.tar.gz file using the following
command:
tar -zxvf MSM_linux_installer-11.02.00-00-...tar.gz
A new disk directory is created.
3. Go to the new disk directory.
4. In the disk directory, find and read the readme.txt file.
5. To start the installation, enter the following command:
csh install.sh -a
If you select Client installation for a computer that is used to monitor servers, and if no
available servers exist with a registered framework on the local subnet (that is, servers
with a complete installation of the MegaRAID Storage Manager software), the
MegaRAID Storage Manager - Host Name window appears. The MegaRAID Storage
Manager - Host Name window does not list any servers. You can use this window to
manage systems remotely.
To install the software using an interactive mode, execute the command ./install.sh
from the installation disk.
To install the product in a non-interactive or silent mode, use the command
./install.sh [-options] [-ru popup]
from the installation disk. The installation
options are as follows:
Complete
Client Component Only
StandAlone
Local
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e