5 migrating the raid level of a virtual drive – Avago Technologies MegaRAID Fast Path Software User Manual
Page 368

Page 368
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 8: Configuration
|
Changing a Virtual Drive Configuration
The dialog with the replacement drive appears, as shown in the following figure.
Figure 239: Drive Replacement Window
4. Select a replacement drive.
A confirmation message appears.
5. Click Yes.
This step replaces a drive and copies the data to the selected component.
8.7.5
Migrating the RAID Level of a
Virtual Drive
As the amount of data and the number of drives in your system increase, you can use
RAID-level migration to change a virtual drive from one RAID level to another. You do
not have to power down or reboot the system when you make this change.
When you migrate a virtual drive to another RAID level, you can keep the same number
of drives, or you can add drives. In some cases, you have to add a certain number of
drives to migrate the virtual drive from one RAID level to another. The window
indicates the minimum number of drives you are required to add.
CAUTION: Be sure to back up the data on the virtual drive before you change the RAID
level.
Follow these steps to change the RAID level of the virtual drive with the Modify Drive
Group wizard:
1. Click the Logical tab in the left panel of the MegaRAID Storage Manager window.
2. Select a drive group in the left panel of the window.
3. Either select Go To>> Drive Group>>Modify Drive Group on the menu bar, or
right-click the virtual drive icon to access the Modify Drive Group wizard.
The Modify Drive Group wizard appears.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e