Chapter 9: Monitoring Controllers and Its Attached Devices
|
Alert Delivery Methods
Chapter 9
The MegaRAID Storage Manager software enables you to monitor the activity of all the
controllers present in the system and the devices attached to them.
When you perform an operation on devices (such as the creation of a new virtual drive)
or when devices automatically go from an optimal state to a different state (such as a
created virtual drive goes to a degraded state or a Battery Backup Unit goes bad), the
MegaRAID Storage Manager software gets those events from the controller and gives a
notification to you, using different alert delivery methods
9.1
Alert Delivery Methods
Based on the severity level (Information, Warning, Critical and Fatal), the default alert
delivery methods change. By default, each severity level has one or more alert delivery
methods configured for it, as shown in
. To modify these alert delivery
methods, see
Configuring Alert Notifications
. The different alert delivery methods are as
follows:
Vivaldi Log/MegaRAID Storage Manager Log
System Log
Pop-up Notification
E-mail Notification
Monitoring Controllers and Its Attached Devices
This chapter explains how to use the MegaRAID Storage Manager software to monitor
the status of drives, virtual drives, and other storage devices.
Table 148: Severity Level and Default Alert Delivery Methods
Severity Level
Default Alert Delivery Method
Meaning
Information
Vivaldi log/MegaRAID Storage
Manager log and System log
Informational message. No
user action is necessary.
Warning
Vivaldi log/MegaRAID Storage
Manager log and System log
Some component might be
close to a failure point.
Critical
Vivaldi log/MegaRAID Storage
Manager log, System log, and
Popup Notification
A component has failed, but
the system has not lost data.
Fatal
Vivaldi log/MegaRAID Storage
Manager log, System log, Popup
Notification, and E-mail Notification
A component has failed, and
data loss has occurred or will
occur.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e