beautypg.com

2 display bbu status information – Avago Technologies MegaRAID Fast Path Software User Manual

Page 239

background image

LSI Corporation Confidential

|

July 2011

Page 239

MegaRAID SAS Software User Guide

Chapter 5: MegaRAID Command Tool

|

Battery Backup Unit-Related Properties

5.11.2

Display BBU Status

Information

Use the command in the following table to display complete information about the
status of the BBU, such as temperature and voltage, for the selected controllers.

Table 64: Display BBU Status Information

Convention

MegaCli -AdpBbuCmd -GetBbuStatus –aN|-a0,1,2|-aALL

Description

Displays complete information about the BBU status, such as the temperature and voltage. The information displays in the
following formats:

BBU Status for Adapter: xx

Battery Type: XXXXXX(string)

Voltage: xx mV

Current: xx mA

Temperature: xx C°

Firmware Status: xx

Battery state: xx

Gas Gauge Status:

Fully Discharged: Yes/No

Fully Charged: Yes/No

Discharging: Yes/No

Initialized: Yes/No

Remaining Time Alarm: Yes/No

Remaining Capacity Alarm: Yes/No

Discharge Terminated: Yes/No

Over Temperature: Yes/No

Charging Terminated: Yes/No

Over Charged: Yes/No

Additional status information displays differently for iBBU and BBU.

For iBBU:

Relative State of Charge: xx

Charger System State: xx

Charger System Ctrl: xx

Charging Current: xx mA

Absolute State of Charge: xx%

Max Error: xx%

For BBU:

Relative State of Charge: xx

Charger Status: xx

Remaining Capacity: xx mAh

Full Charge Capacity: mAh

isSOHGood: Yes/No