Event Messages
0x0143
Fatal
Controller cache pinned for missing or offline VD %s
0x0144
Fatal
Controller cache pinned for missing or offline VDs: %s
0x0145
Information
Controller cache discarded by user for VDs: %s
0x0146
Information
Controller cache destaged for VD %s
0x0147
Warning
Consistency Check started on an inconsistent VD %s
0x0148
Warning
Drive security key failure, cannot access secured
configuration
0x0149
Warning
Drive security password from user is invalid
0x014a
Warning
Detected error with the remote battery connector cable
0x014b
Information
Power state change on PD %s from %s to %s
0x014c
Information
Enclosure %s element (SES code 0x%x) status changed
0x014d
Information
PD %s rebuild not possible as HDD/CacheCade software mix
is not supported in a drive group
0x014e
Information
Copyback cannot be started on PD %s from %s, as
HDD/CacheCade software mix is not supported in a drive
group
0x014f
Information
VD bad block table on %s is cleared
0x0150
Caution
SAS topology error: 0x%lx
0x0151
Information
VD cluster of medium errors corrected for %s at %lx (on %s at
%lx)
0x0152
Information
Controller requests a host bus rescan
0x0153
Information
Controller repurposed and factory defaults restored
0x0154
Information
Drive security key binding updated
0x0155
Information
Drive security is in EKM mode
0x0156
Warning
Drive security failed to communicate with EKMS
0x0157
Information
%s needs key to be %s %s
0x0158
Warning
%s secure failed
0x0159
Critical
Controller encountered a fatal error and was reset
0x015a
Information
Snapshots enabled on %s (Repository %s)
0x015b
Information
Snapshots disabled on %s (Repository %s) by the user
0x015c
Critical
Snapshots disabled on %s (Repository %s), due to a fatal error
0x015d
Information
Snapshot created on %s at %s
0x015e
Information
Snapshot deleted on %s at %s
0x015f
Information
View created at %s to a snapshot at %s for %s
0x0160
Information
View at %s is deleted, to snapshot at %s for %s
0x0161
Information
Snapshot rollback started on %s from snapshot at %s
0x0162
Fatal
Snapshot rollback on %s internally aborted for snapshot at %s
0x0163
Information
Snapshot rollback on %s completed for snapshot at %s
0x0164
Information
Snapshot rollback progress for snapshot at %s, on %s is %s
0x0165
Warning
Snapshot space for %s in snapshot repository %s, is 80%% full
Table 150: Event Messages (Continued)
Number
Severity Level
Event Text
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e