6 manage a drive initialization, 7 rebuild a drive – Avago Technologies MegaRAID Fast Path Software User Manual
Page 256

Page 256
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 5: MegaRAID Command Tool
|
Drive-Related Options
5.15.6
Manage a Drive Initialization
Use the command in the following table to manage a drive initialization on the
selected controllers.
5.15.7
Rebuild a Drive
Use the command in the following table to start or stop a rebuild on a drive and display
the rebuild progress. When a drive in a RAID drive group fails, you can rebuild the drive
by re-creating the data that was stored on the drive before it failed.
Table 102: Drive Initialization
Convention
MegaCli –PDClear -Start |-Stop|-ShowProg |-ProgDsply
-PhysDrv[E0:S0,E1:S1....] -aN|-a0,1,2|-aALL
Description
Manages initialization or displays initialization progress on a single
controller, multiple controllers, or all controllers:
-Start
: Starts initialization on the selected drives.
-Stop
: Stops an ongoing initialization on the selected drives.
-ShowProg
: Displays the current progress percentage and time remaining
for the initialization. This option is useful for running the application through
scripts.
-ProgDsply
: Displays the ongoing clear progress. The routine continues
to display the initialization progress until at least one initialization is
completed or a key is pressed.
Table 103: Rebuild a Drive
Convention
MegaCli –PDRbld –Start
|-Stop|-Suspend|-Resume|-ShowProg |-ProgDsply
–PhysDrv [E0:S0,E1:S1....] -aN|-a0,1,2|-aALL
Description
Manages a drive rebuild or displays the rebuild progress on a single
controller, multiple controllers, or all controllers. Note that the drive must
meet the capacity requirements before it can be rebuilt, and it must be part
of a drive group:
-Start
: Starts a rebuild on the selected drives and displays the rebuild
progress (optional).
-Stop
: Stops an ongoing rebuild on the selected drives.
-Suspend
: Suspends the rebuild.
-Resume
: Resumes the rebuild from the point that the rebuild was
suspended.
-ShowProg
: Displays the current progress percentage and time remaining
for the rebuild. This option is useful for running the application through
scripts.
-ProgDsply
: Displays the ongoing rebuild progress. This routine displays
the rebuild progress until at least one initialization is completed or a key is
pressed.
-Physdrv[E0:S0,...]
: Specifies the physical drive enclosure and the
slots for the drives.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e