3 create secure virtual drives, 4 import a foreign configuration, 5 instant secure erase – Avago Technologies MegaRAID Fast Path Software User Manual
Page 50: Section 3.5, Instant secure erase
Page 50
LSI Corporation Confidential
|
July 2011
MegaRAID SAS Software User Guide
Chapter 3: SafeStore Disk Encryption
|
Instant Secure Erase
3.4.3
Create Secure Virtual Drives
You can create a secure virtual drive and set its parameters as desired. To create a
secure virtual drive, select a configuration method. You can select either simple
configuration or advanced configuration.
3.4.3.1
Simple Configuration
If you select simple configuration, select the redundancy type and drive security
method to use for the drive group.
See
Section 8.1.4, Creating a Virtual Drive Using Simple Configuration
for the procedures
used to select the redundancy type and drive security method for a configuration.
3.4.3.2
Advanced Configuration
If you select advanced configuration, select the drive security method, and add the
drives to the drive group.
See
Section 8.1.5, Creating a Virtual Drive using Advanced Configuration
for the
procedures used to import a foreign configuration.
After the drive group is secured, you cannot remove the security without deleting the
virtual drives.
3.4.4
Import a Foreign Configuration
After you create a security key, you can run a scan for a foreign configuration and
import a locked configuration. (You can import unsecured or unlocked configurations
when security is disabled.) A foreign configuration is a RAID configuration that already
exists on a replacement set of drives that you install in a computer system. WebBIOS
Configuration Utility and the MegaRAID Storage Manager software allows you to
import the existing configuration to the RAID controller or clear the configuration so
you can create a new one.
See
Section 4.8, Viewing and Changing Device Properties
for the procedure used to
import a foreign configuration in WebBIOS or
Section 11.6.12, Importing or Clearing a
for the procedure in the MegaRAID Storage Manager software.
To import a foreign configuration, you must first enable security to allow importation of
locked foreign drives. If the drives are locked and the controller security is disabled, you
cannot import the foreign drives. Only unlocked drives can be imported when security
is disabled.
After you enable the security, you can import the locked drives. To import the locked
drives, you must provide the security key used to secure them. Verify whether any
drives are left to import as the locked drives can use different security keys. If there are
any drives left, repeat the import process for the remaining drives. After all of the drives
are imported, there is no configuration to import.
3.5
Instant Secure Erase
Instant Secure Erase is a feature used to erase data from encrypted drives. After the
initial investment for an encrypted disk, there is no additional cost in dollars or time to
erase data using the Instant Secure Erase feature.
You can change the encryption key for all MegaRAID RAID controllers that are
connected to encrypted drives. All encrypted drives, whether locked or unlocked,
always have an encryption key. This key is set by the drive and is always active. When
the drive is unlocked, the data to host from the drive (on reads) and from the host to
the drive cache (on writes) is always provided. However, when resting on the drive
platters, the data is always encrypted by the drive.
- MegaRAID SAS 9240-4i MegaRAID SAS 9240-8i MegaRAID SAS 9260-16i MegaRAID SAS 9260-4i MegaRAID SAS 9260-8i MegaRAID SAS 9261-8i MegaRAID SAS 9280-16i4e MegaRAID SAS 9280-4i4e MegaRAID SAS 9280-8e MegaRAID SafeStore Software MegaRAID SAS 9361-4i MegaRAID SAS 9361-8i MegaRAID SAS 9266-4i MegaRAID SAS 9266-8i MegaRAID SAS 9270-8i MegaRAID SAS 9271-4i MegaRAID SAS 9271-8i MegaRAID SAS 9271-8iCC MegaRAID SAS 9286-8e MegaRAID SAS 9286CV-8e MegaRAID SAS 9286CV-8eCC MegaRAID CacheCade Pro 2.0 Software MegaRAID SAS 9341-4i MegaRAID SAS 9341-8i MegaRAID SAS 9380-8e MegaRAID SAS 9380-4i4e